| Water Quality Monitoring |
|
Water stored from the house roof top is presumed to be pure and potable as it will not flow on the ground and come into contact with any liquid or solid
materials which can alter its quality. But, the rainwater falls on the
roof, passes through the gutters and finally reaches the storage tank.
In this process, water comes into contact with the dust, debris and leaf
litter collected on the roof and the gutters. The water collected in the
tank is stored for a period of 3 to 6 months before use. During this period,
water will be in contact with tank walls and pipe fittings in the storage
tank. If the stored water is exposed to outer environment it allows growth
of algae and breeding of mosquitoes in the tank.
The reasons for variations in chemical constituents and bacteriological properties of water from Rooftop Rainwater Harvesting system (RRHS) could be many but the most important ones are listed below: |
|
| Analysis of Water samples |
| As
the bacteriological contamination cannot be detected by the naked eye, it
is necessary to analyse the quality of water in laboratories by collecting
few water samples from storage tank. These tests help in verifying the presence
of pathogenic bacteria. Following is the procedure for sample collection: |
Disinfecting is the process of killing the disease causing micro-organism present in the water. This can be done either by boiling the water in a vessel before consuming or by dissolving bleaching powder in required quantity to the water stored in the tank. For disinfecting using bleaching powder, the general dosage recommended is 10 milligrams of bleaching powder containing 25% of free chlorine per litre of water. this meets the required standard of 2.5 milligrams of chlorine per litre of water. After adding the bleaching powder, the water shall be stirred thoroughly for even distribution of the disinfectant agent. The water should be kept without use for about 30 minutes after adding bleaching powder. Following table can be referred for arriving at the quantity of bleaching powder to be added for different water depths in the storage tank. |
|
Recommended
dosage of bleaching powder for Disinfecting water
|
| Storage |
Dosage
of bleaching powder ( in grams )
|
| capacity of tank (litre) |
Full
tank
|
Tank three fourth (3/4) full |
Tank
half (1/2) full
|
Tank
one fourth (1/4) full
|
|
5,000
|
50
|
37.5
|
25
|
12.5
|
|
6,000
|
60
|
45
|
30
|
15
|
|
7,000
|
70
|
52.5
|
35
|
17.5
|
|
8,000
|
80
|
60
|
40
|
20
|
|
9,000
|
90
|
67.5
|
45
|
22.5
|
|
10,000
|
100
|
75
|
50
|
25
|
![]() |